Compressors and compressor units FAS/CORKEN type
- Customer pickup,
- Courier
- In detail
The FAS-set compressor unit with the piston compressor of the dry course of PN 25.
- for installation on the compressor sites equipped with gas flow pereklyucheniyanapravleniye "comb" the filtriruyushchy and control and safety equipment mounted in pipelines
- electric motor in the dust-ignition-proof construction V-belt transmission
- the strengthened support frame, otgruntovana is also varnished
Zakaz-Nr. | Motor, kW | Type | Makimalnaya Proizvod. (m3/h) |
210141 | 3,6 | 91 | 13 |
210930 | 5 | 161 | 28 |
210952 | 10 | 361 | 60 |
210640 | 17,5 | 601 | 102 |
218201 | 30 | 942 | 180 |
Technical datas:
Piston compressor unit of the dry course of FAS ______
Number of the order: FAS-Nr. __________
The BASIC VERSION, STANDARD COMPLETE SET for propane/butane pumping,
consisting from:
- The Type 91 compressor, with the cylinder with simple stub
max. outlet pressure of 23 bars
max. productivity near _____ m3/h
- EExeIIT3 electric motor, 230/400V, ____ kW, 50 Hz with V-belt transmission and the protection cover
with the relief valve
- tension of drive belt, drive belt and washer of drive belt
entrance: (the inhausting party) DU flange ____, the splitter of fluid phase of DN 25 PN 25 FAS with the locking valve for condensate, the manometer 0-25 bar
exit (delivery party): the relief valve of 19 bars, the manometer of 0-25 bars, Du's flange ______, is completely installed on the strengthened frame from steel, ogruntovan and painted, with the factory certificate 2.2 according to EN 10204
Additional repair parts, accessories, safety and inspection equipment for piston compressors:
26 922 - the Board of electromanagement with control of the minimum and maximum pressure, overflow check of the liquid splitter, the double switch and the device of sound and light control.
26 932 - the Board of electromanagement to the compressor unit for mounting in the room and out of explosive zone, is prepared for connection of electric motor ____ by kW with connection star/triangle, control of the minimum and maximum pressure of gas, sensor of control of level on the gas-splitter, control of minimum pressure of oil of the compressor, gas temperature monitoring, the double switch with control light and audio signal, is completely built and ready to connection
21 130 - the Mechanical splitter of PN25 liquid the FAS type, material - steel, the steel sharovy valve 3/8" NPT for condensate descent compliance to norms of AD and TRB the certificate 3.1 EN 10 204, possibility of connection of electronic safety system of shutdown of the compressor, volume - 5,8 l, weight - 18,4 kg
21 195 - the Rack for fastening of devices of pressure monitoring on the general frame (incl. mounting and the pipeline)
26 316 - the Protecting tube for the thermometer form D 1, material: With 22.8, the M18 x 1,5 mm IG connection, (for FAS-Nr. 26.312)
21 193 - the Hose with metalbraid (vibroinsert for system of the pipeline, DN50, PN 40, from stainless steel, l=1000 mm length on both sides free flanges of DN 50, with unary braid from stainless steel
939854 - Anti-vibration set for decrease in vibration and prevention of hit of fluid phase to the delivery line of the compressor FAS 942 unit