The defibrillator monitor of D500 is intended for use by the trained medical technicians, doctors, nurses or specialists in the field of medicine for rendering emergency medical service in the room and on the street, including a hospital aircraft and an ambulance car within the specified environment conditions.
The displayed parameters
- Manual and automatic outside defibrillation
- external cardiostimulation and other functions of monitoring (electrocardiography (electrocardiogram))
- functional saturation of hemoglobin of an arterial blood oxygen (SpO2)
- respiration (RESP)
- temperature (SPEED)
- the invasive arterial pressure (IAP) and concentration of CO2 at the end of a quiet exhalation (EtCO2) are intended for adult patients and children.
- noninvasive arterial pressure is measured at adult patients, children and newborns.
Features
- Portability. Availability of the recharged accumulator. Possibility of power supply from two accumulators (option)
- The defibrillator monitor has epoch - making function of ECG monitoring with use of the advanced software for the analysis of electrocardiograms developed by University of Glasgow (Great Britain), including processing of signals, diagnostic reading electrocardiograms of patients of any age and the analysis of a cordial rhythm.
- Availability of voice hints, messages
- Continuous use
- The device keeps the previous settings if it is switched - off no more than for 10 seconds. And if the defibrillator monitor was not disconnected, and passed more than 10 minutes from the moment of the last use of an operating mode, the defibrillator monitor keeps the previous settings of the last operating mode
- Setup of date, time, introduction of data on the patient (ID, name, age, sex)
- Data transmission by means of 3G, the wireless Wi - fi network
- Nest for the USB/SD card
Special functions
- List of clinical actions. Display of information on use of medicines
- Testing of buttons. Possibility of check of correctness of functioning of buttons
Technical characteristics of a defibrillator monitor of D500:
Name |
Parameters |
|
Display |
||
Screen size |
The LCD display of thin - film technology with diagonal 8.4dyuyma |
|
Screen type |
Liquid crystal color display |
|
Size |
170 x 128 mm |
|
Quantity of curves of the recorder |
4 curves |
|
Control system |
||
Standard |
Universal switch; The operating mode Switch (It is switched off, the ANDES, the manual mode, electrocardiostimulation and the monitor); 11 buttons (Category, energy Level, Recharge, Analysis, NIAD, Assignment, Emergency and precautionary alarm system, Size, Press, Frequency, ma); 5 function keys |
|
Emergency and precautionary alarm system |
||
Categories |
Condition of the patient and Condition of system |
|
Priorities |
Low, Average and High priorities |
|
The notifying message |
Sound and visual |
|
Settings |
Standard and Individual |
|
Level of loudness of the alarming alarm system |
From 45 to 85 dB |
|
Physical characteristics |
||
Device |
|
|
Sizes |
340 x 305 x 210 (mm) (SHKHVKHG), including the accumulator and excepting electrodes, the additional equipment and accessories |
|
Weight |
About 6: 16 (kg) including the accumulator and excepting electrodes, the additional equipment and accessories. |
|
Operating mode |
Continuous |
|
Classification |
Class IIb (MDD Rev.8 Pravilo10: meddev 2.4/1 Appendix IX) |
|
Printer |
||
Type |
Thermographic |
|
Weight |
190 g |
|
Number of channels |
From 1 to 3 channels |
|
Paper type |
For the thermopress |
|
Paper width |
80 mm |
|
Press speed |
25 mm / page, 50 mm / page. |
|
Electric parameters |
||
Alternating current main |
From 100 to 240 V, 50/60 Hz, 160 BA |
|
Network of a direct current |
Direct current of 18 V, 7.0 A with the converter of tension of a direct current, |
|
Note: For connection to a network of 120 volts it is necessary to use only an admissible removable cord of food of UL with a plug fork of a configuration of 5 - 15 P NEMA (with parallel knife contacts). For connection to a network of 240 volts it is necessary to use only an admissible removable cord of power supply of UL with a plug fork of a configuration of 6 - 15P NEMA (with consecutive knife contacts). |
||
Accumulator (option) |
||
Type |
Lithium - ion accumulator |
|
Sizes |
150 x 90 x 20 (mm) (ShhVhG) |
|
Tension/Capacity |
4S2P 14.4 In / 5200ma/h. |
|
Accumulator discharge |
Not less than 200 categories on 200 J (on the accumulator) |
|
Period of operation |
5 hours (on the accumulator), 10 hours (with two batteries) At observance of the following conditions: Without printout Without external communications Without sound warning sign Room temperature: 25 °C |
|
Recharge |
More than 8 hours at the included/switched off defibrillator/monitor (The Full charge of the accumulator takes about 8 hours the moment of operation of a signal of a low charge of the accumulator). |
|
Service life |
6 months, the new completely charged accumulator ( - Service life of the accumulator can vary depending on the number of recharge, working temperature and storage conditions. As a rule, after 300 cycles of recharge there can be about 80% of capacity of the accumulator. If one cycle of recharge makes 2 or 3 days, then approximately in 24 months the capacity of the accumulator will be 80% . - For the purpose of safety the accumulator cannot be charged at a temperature of 40 °C. ) After 2 months of storage of the defibrillator/monitor operating time of the accumulator will make 50% of declared. |
|
Service conditions |
||
Range of measurement of temperature |
From 0 to 50 °C (from 32 to 122 °F) |
|
Humidity |
relative humidity from 15 to 95% , without formation of condensate |
|
Height above sea level |
From - 170 to 4 877 m (from - 557 to 16 000 feet) |
|
Note: In case of storage or use in conditions outside the specified range of temperature and humidity, the system can not correspond to the operational characteristics. Note: For the purpose of safety the accumulator cannot be charged at a working temperature above 40 °C. |
||
Transportation and storage (in transport packaging) |
||
Temperature |
From - 20 °C to 70 °C (from - 4 °F to 158 °F) |
|
Humidity |
Relative humidity from 15 to 95% , without formation of condensate |
|
Height above sea level |
From - 304 to 6,096 m (from - 1,000 to 20,000 feet) |
|
Note: In case of storage or use in conditions outside the specified range of temperature and humidity, the system can not correspond to the operational characteristics. |
||
Installations of a sound signal |
||
Warning sign of a high priority |
||
Loudness level |
Regulated (level 1 ~ 8) |
|
Tone height (± 48.8gts) |
976 Hz |
|
Impulse duration (± 10 ms) |
210 ms |
|
Number of impulses |
10 impulses in 4 sec. , 10 sec. between impulses |
|
Repetition |
Continuously |
|
Warning sign of an average priority |
||
Loudness level |
Regulated (level 1 ~ 8) |
|
Tone height (± 34.85 Hz) |
697 Hz |
|
Impulse duration (± 10 ms) |
210 ms |
|
Number of impulses |
3 impulses in 1 sec. , 15 sec. between impulses |
|
Repetition |
Continuously |
|
Warning sign of a low priority |
||
Loudness level |
Regulated (level 1 ~ 8) |
|
Tone height (± 9.4 Hz) |
488 Hz |
|
Impulse duration (± 10 ms) |
210 ms |
|
Number of impulses |
1 impulse in 0: 25 sec. , 30 sec. between impulses |
|
Warning sign of a reminder |
||
Loudness level |
Non - regulated |
|
Tone height (± 40 Hz) |
800 Hz |
|
Impulse duration (± 10 ms) |
200 ms |
|
Number of impulses |
1 impulse in 1 sec. , 3 min. , 10 min. between impulses |
|
Repetition |
Continuously |
|
Sound signal of ChSS/ChP |
||
Loudness level |
Non - regulated |
|
Tone height (± 32.5 Hz) |
650 Hz (ECG) (162 + 5 * SpO2) Hz |
|
Impulse duration (± 5 ms) |
100 ms |
|
Number of impulses |
N of. |
|
Repetition |
Does not repeat |
|
Sound signal when pressing a key |
||
Loudness level |
Regulated (It is switched off, level 1 ~ 7) |
|
Tone height |
440 (± 22) Hz (operating) 168 (± 8.4) Hz (invalid) |
|
Impulse duration (± 5 ms) |
100 ms |
|
Number of impulses |
N of. |
|
Repetition |
Does not repeat |
|
Parameters of measurements |
||
Electrocardiostimulation mode |
||
Stimulation frequency |
Changes ranging from 30 ud. / min. to 180 ud. / min. ± 1.5% (min. increases or decreases by size of 2 ud. /) |
|
Permission |
2 ud. / min. |
|
Accuracy |
± 1.5% |
|
Current at the exit |
From 0 ma to 140 ma |
|
Permission |
2 ma |
|
Accuracy |
± 5% or 5 ma that it is more |
|
Type of an impulse |
Impulse of a direct current lasting 40 ms |
|
Impulse amplitude |
Changes ranging from 0 ma to 140 ma ± 5% or 5 ma, depending on what of sizes is more. In a digital form it is displayed on the defibrillator/monitor (increases or decreases by size of 2 ma) |
|
Mode of the ANDES |
||
Assignment |
Assignment of ll |
|
Patient's impedance |
От 25 до 175 Ohm |
|
CHSS |
From 20 to 300 ud. / min. |
|
Accuracy |
1 in a minute |
|
Detection |
N/H N / In |
|
Time of the analysis of the category |
||
Duration of charging is up to 200 J * |
Within 6 seconds with a rated voltage of a network/tension of a network of a direct current Within 7 seconds with completely charged battery |
|
* Data on charging duration in other cases see in the technical specification of a defibrillator |
||
Manual control mode |
||
Discharge energy level |
External electrodes: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 300, 360 J |
|
Time of the automatic category |
60 seconds |
|
Duration of charging is up to 360 J |
Within 8 seconds with a rated voltage of a network/tension of a network of a direct current Within 9 seconds with completely charged battery |
|
* Data on charging duration in other cases see in the technical specification of a defibrillator |
||
CHSS |
||
Measuring range |
From 0, 20 to 300 ud. / min. |
|
Permission |
1 ud. / min. |
|
Accuracy |
± 10% or ± 5 beats per minute that it is more |
|
Average time of expectation |
5 seconds (from 80 do120 ud. / min. ) |
|
9 seconds (from 80 to 40 ud. / min. ) |
||
Excessive deviation of the T - tooth |
Amplitude of the T - tooth is no more than 1.8 mV |
|
ECG (Elektrokardiograf) |
||
Assignments |
3 / 5 / 12 Assignment (Assignment of I, II, III, aVR, aVL, aVF, V, V1, V2, |
|
V3, V4, V5, V6) |
||
Utyuzhkovy electrode / electrode |
||
Assignment shutdown detection |
It is found and displayed |
|
Detection of a pacemaker |
Finds pacemaker impulses from ±2мВ to ±700мВ, lasting impulse from 0.1 to 2 ms and time of increase of 10% of duration no more than 100 ms |
|
Input data |
||
Impedance of an entrance electrode |
5 Megohm or more |
|
Dynamic range on an entrance |
±5 mV alternating current, ±300 mV direct current |
|
Range of tension |
±0.5 mV ~ ±5 mV |
|
Signal width |
From 40 to 120 ms (from Q to S) |
|
Output |
||
Filter mode |
От 0.5 до 21 Hz |
|
От 0.05 до 40 Hz |
||
От 1 до 21 Hz |
||
ECG size |
Car, 5.0, 10.0, 15.0, 20.0, 30.0 mm/mV |
|
Display rate of display |
25.0 mm / with |
|
Tooth size |
x0.5, x1, x1.5, x2, x3 |
|
Sensitivity of the display |
10 mm/mV (x1) |
|
Detection of impulses of cardiostimulation |
It is included, switched off |
|
Warning sign of a detachment of an electrode |
Display and/or sound signal |
|
Extinction coefficient of a cophased signal |
90 dB or more |
|
Category of a defibrillator Recovery of operating state |
||
Protection of a defibrillator |
Protected |
|
Breath of IM |
||
Method |
Impedance pneumography |
|
Range |
From 0,3 to 120 breaths/min. |
|
Permission |
1 breath/min. |
|
Assignments |
From software to LP |
|
Basic impedance |
От 500 до 2000 Ohm |
|
Delta impedance |
От 0.5 до 3 Ohm |
|
Assignment shutdown conditions |
It is revealed and displayed |
|
Protection of a defibrillator |
It is protected |
|
Display rate of display |
25 mm / with |
|
Tooth size |
x0.5, x1, x1.5, x2 |
|
Breath of AW |
||
Method |
Not dispersive infrared spectroscopy |
|
Range |
From 0 to 150 breaths/min. |
|
Accuracy |
±1 breath/min. |
|
Pulse rate range |
||
Adults/children |
From 40 to 200 ud. / min. |
|
Newborns |
From 40 to 240 ud. / min. |
|
Permission |
5 ud. / min. |
|
Accuracy of measurement of state of emergency |
±2 ud. / min. Or ±2% , depending on what value is more |
|
NIAD (Noninvasive arterial pressure) |
||
Method |
Ostsillometrichesky method of measurement |
|
Mode of measurements |
It is switched off, continuously, 1, 2.5, 3, 5, 10, 15, 30, 60, 90 minutes |
|
Measuring range |
||
Adults/children |
||
Systolic |
from 60 to 250 mm of mercury. |
|
Average |
from 45 to 235 mm of mercury. |
|
Diastolic |
from 40 to 200 mm of mercury. |
|
Newborns |
||
Systolic |
from 40 to 120 mm of mercury. |
|
Average |
from 30 to 100 mm of mercury. |
|
Diastolic |
from 20 to 90 mm of mercury. |
|
Accuracy of measurement of NIAD |
Average error and standard deviation on ANSI/AAMI SP10: 2002 + A1: 2003 + A2: 2006 |
|
Range of display of pressure |
||
Adults/children |
from 0 to 300 mm of mercury. |
|
Newborns |
from 0 to 150 mm of mercury. |
|
Display of data on pressure (accuracy) |
Within ±3 mm hg or 2% |
|
Initial pressure of air in a cuff |
|
|
Adults/children |
120, 140, 160, 180, 200, 220, 240, 260, 280 mm of mercury. (16.0, 18.7, 21.3, 24.0, 26.7, 29.3, 32.0, 34.7, 37.3 kPa) |
|
Newborns |
80, 90, 100, 110, 120, 130, 140 mm of mercury. (10.7, 12.0, 13.3, 14.7, 16.0, 17.3, 18.7 kPa) |
|
Automatic sduvaniye of a cuff |
The measurement time exceeding 180 with at adults/children (90 with at newborns) or the maximum value of pressure exceeding 300 mm of mercury. at adults (150 mm of mercury. at newborns). |
|
Protection against excessive pressure |
Adults/children: 300 mm of mercury. Newborns: 150 mm of mercury. |
|
Protection of a defibrillator |
It is protected |
|
Measurement speed |
About 20 seconds Under following conditions: Adults The size of a cuff is 12 cm Systolic 120 mm of mercury. Average of 90 mm of mercury. Diastolic 80 mm hg / state of emergency 80 ud. / min. Measurement in the manual mode (180 mm of mercury. )
|
|
IAD |
||
Pulse rate |
||
Pulse rate range |
From 20 to 250 ud. / min. |
|
Accuracy |
± 1% or ± 1 ud. / min. |
|
Permission of pulse rate |
1 ud. / min. |
|
IAP (Invasive Arterial Pressure) |
||
The displayed indicator |
P1, ABP P2, CVP, PAP, LAP |
|
Measuring range |
From - 50 mm of mercury. to 300 mm of mercury. From 20 ud. / min. to 250 ud. / min. |
|
Permission |
1 mm of mercury. |
|
Accuracy |
± 3 mm of mercury. |
|
Entrance sensitivity |
5 mkv/v/mm рт. ст. |
|
Volume shift of the sensor |
0.1 mm3/100mm hg. |
|
Range of calibration of zero |
± 100 mm of mercury. |
|
Frequency characteristic |
Direct current - 10 Hz ± 1 Hz, - 3 dB |
|
Tooth size |
From 0 to 50, from 0 to 100, from 0 to 200, from 0 to 300, car size |
|
Display rate of display |
25.0 mm / with |
|
Protection of a defibrillator |
It is protected |
|
SpO2 |
||
Measuring ranges |
||
Area of saturation SpO2 |
1% to 100% |
|
Range of measurement of state of emergency |
From 20 to 300 beats per minute (ud. / min. ) |
|