Currency KZT
Defibrillator – the D500 monitor buy in Almaty
Buy Defibrillator – the D500 monitor
Defibrillator – the D500 monitor

Defibrillator – the D500 monitor

In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Kazakhstan, Almaty
(View map)
+7(7 
Display phones
9
9 years on Allbiz
Quickly responds
Description

The defibrillator monitor of D500 is intended for use by the trained medical technicians, doctors, nurses or specialists in the field of medicine for rendering emergency medical service in the room and on the street, including a hospital aircraft and an ambulance car within the specified environment conditions.

The displayed parameters

  • Manual and automatic outside defibrillation
  • external cardiostimulation and other functions of monitoring (electrocardiography (electrocardiogram))
  • functional saturation of hemoglobin of an arterial blood oxygen (SpO2)
  • respiration (RESP)
  • temperature (SPEED)
  • the invasive arterial pressure (IAP) and concentration of CO2 at the end of a quiet exhalation (EtCO2) are intended for adult patients and children.
  • noninvasive arterial pressure is measured at adult patients, children and newborns.

 Features

  • Portability. Availability of the recharged accumulator. Possibility of power supply from two accumulators (option)
  • The defibrillator monitor has epoch - making function of ECG monitoring with use of the advanced software for the analysis of electrocardiograms developed by University of Glasgow (Great Britain), including processing of signals, diagnostic reading electrocardiograms of patients of any age and the analysis of a cordial rhythm.
  • Availability of voice hints, messages
  • Continuous use
  • The device keeps the previous settings if it is switched - off no more than for 10 seconds. And if the defibrillator monitor was not disconnected, and passed more than 10 minutes from the moment of the last use of an operating mode, the defibrillator monitor keeps the previous settings of the last operating mode
  • Setup of date, time, introduction of data on the patient (ID, name, age, sex)
  • Data transmission by means of 3G, the wireless Wi - fi network
  • Nest for the USB/SD card

 Special functions

  • List of clinical actions. Display of information on use of medicines
  • Testing of buttons. Possibility of check of correctness of functioning of buttons 

Technical characteristics of a defibrillator monitor of D500:

Name

Parameters

Display

Screen size

The LCD display of thin - film technology with diagonal 8.4dyuyma

Screen type

Liquid crystal color display

Size

170 x 128 mm

Quantity of curves of the recorder

4 curves

Control system

Standard

Universal switch; The operating mode Switch (It is switched off, the ANDES, the manual mode, electrocardiostimulation and the monitor); 11 buttons (Category, energy Level, Recharge, Analysis, NIAD, Assignment, Emergency and precautionary alarm system, Size, Press, Frequency, ma); 5 function keys

Emergency and precautionary alarm system

Categories

Condition of the patient and Condition of system

Priorities

Low, Average and High priorities

The notifying message

Sound and visual

Settings

Standard and Individual

Level of loudness of the alarming alarm system

From 45 to 85 dB

Physical characteristics  

Device

 

Sizes

340 x 305 x 210 (mm) (SHKHVKHG), including the accumulator and excepting electrodes, the additional equipment and accessories

Weight

About 6: 16 (kg) including the accumulator and excepting electrodes, the additional equipment and accessories.

Operating mode

Continuous

Classification

Class IIb (MDD Rev.8 Pravilo10: meddev 2.4/1 Appendix IX)

Printer

Type

Thermographic

Weight

190 g

Number of channels

From 1 to 3 channels

Paper type

For the thermopress

Paper width

80 mm

Press speed

25 mm / page, 50 mm / page.

Electric parameters

Alternating current main

From 100 to 240 V, 50/60 Hz, 160 BA

Network of a direct current

Direct current of 18 V, 7.0 A with the converter of tension of a direct current,

Note: For connection to a network of 120 volts it is necessary to use only an admissible removable cord of food of UL with a plug fork of a configuration of 5 - 15 P NEMA (with parallel knife contacts). For connection to a network of 240 volts it is necessary to use only an admissible removable cord of power supply of UL with a plug fork of a configuration of 6 - 15P NEMA (with consecutive knife contacts).

Accumulator (option)

Type

Lithium - ion accumulator

Sizes

150 x 90 x 20 (mm) (ShhVhG)

Tension/Capacity

4S2P 14.4 In / 5200ma/h.

Accumulator discharge

Not less than 200 categories on 200 J (on the accumulator)

Period of operation

5 hours (on the accumulator), 10 hours (with two batteries)

At observance of the following conditions:

Without printout

Without external communications

Without sound warning sign

Room temperature: 25 °C

Recharge

More than 8 hours at the included/switched off defibrillator/monitor (The Full charge of the accumulator takes about 8 hours the moment of operation of a signal of a low charge of the accumulator).

Service life

6 months, the new completely charged accumulator

( - Service life of the accumulator can vary depending on the number of recharge, working temperature and storage conditions. As a rule, after 300 cycles of recharge there can be about 80% of capacity of the accumulator. If one cycle of recharge makes 2 or 3 days, then approximately in 24 months the capacity of the accumulator will be 80% .

- For the purpose of safety the accumulator cannot be charged at a temperature of 40 °C. )

After 2 months of storage of the defibrillator/monitor operating time of the accumulator will make 50% of declared.

Service conditions 

Range of measurement of temperature

From 0 to 50 °C (from 32 to 122 °F)

Humidity

relative humidity from 15 to 95% , without formation of condensate

Height above sea level

From - 170 to 4 877 m (from - 557 to 16 000 feet)

Note: In case of storage or use in conditions outside the specified range of temperature and humidity, the system can not correspond to the operational characteristics.

Note: For the purpose of safety the accumulator cannot be charged at a working temperature above 40 °C.

Transportation and storage (in transport packaging)

Temperature

From - 20 °C to 70 °C (from - 4 °F to 158 °F)

Humidity

Relative humidity from 15 to 95% , without formation of condensate

Height above sea level

From - 304 to 6,096 m (from - 1,000 to 20,000 feet)

Note: In case of storage or use in conditions outside the specified range of temperature and humidity, the system can not correspond to the operational characteristics.

Installations of a sound signal 

Warning sign of a high priority

Loudness level

Regulated (level 1 ~ 8)

Tone height (± 48.8gts)

976 Hz

Impulse duration (± 10 ms)

210 ms

Number of impulses

10 impulses in 4 sec. , 10 sec. between impulses

Repetition

Continuously

Warning sign of an average priority

Loudness level

Regulated (level 1 ~ 8)

Tone height (± 34.85 Hz)

697 Hz

Impulse duration (± 10 ms)

210 ms

Number of impulses

3 impulses in 1 sec. , 15 sec. between impulses

Repetition

Continuously

Warning sign of a low priority

Loudness level

Regulated (level 1 ~ 8)

Tone height (± 9.4 Hz)

488 Hz

Impulse duration (± 10 ms)

210 ms

Number of impulses

1 impulse in 0: 25 sec. , 30 sec. between impulses

Warning sign of a reminder

Loudness level

Non - regulated

Tone height (± 40 Hz)

800 Hz

Impulse duration (± 10 ms)

200 ms

Number of impulses

1 impulse in 1 sec. , 3 min. , 10 min. between impulses

Repetition

Continuously

Sound signal of ChSS/ChP

Loudness level

Non - regulated

Tone height (± 32.5 Hz)

650 Hz (ECG)

(162 + 5 * SpO2) Hz

Impulse duration (± 5 ms)

100 ms

Number of impulses

N of.

Repetition

Does not repeat

Sound signal when pressing a key

Loudness level

Regulated (It is switched off, level 1 ~ 7)

Tone height

440 (± 22) Hz (operating)

168 (± 8.4) Hz (invalid)

Impulse duration (± 5 ms)

100 ms

Number of impulses

N of.

Repetition

Does not repeat

Parameters of measurements 

Electrocardiostimulation mode

Stimulation frequency

Changes ranging from 30 ud. / min. to 180 ud. / min. ± 1.5% (min. increases or decreases by size of 2 ud. /)

Permission

2 ud. / min.

Accuracy

± 1.5%

Current at the exit

From 0 ma to 140 ma

Permission

2 ma

Accuracy

± 5% or 5 ma that it is more

Type of an impulse

Impulse of a direct current lasting 40 ms

Impulse amplitude

Changes ranging from 0 ma to 140 ma ± 5% or 5 ma, depending on what of sizes is more. In a digital form it is displayed on the defibrillator/monitor (increases or decreases by size of 2 ma)

Mode of the ANDES

Assignment

Assignment of ll

Patient's impedance

От 25 до 175 Ohm

CHSS

From 20 to 300 ud. / min.

Accuracy

1 in a minute

Detection

N/H

N / In

Time of the analysis of the category

Duration of charging is up to 200 J *

Within 6 seconds with a rated voltage of a network/tension of a network of a direct current

Within 7 seconds with completely charged battery

* Data on charging duration in other cases see in the technical specification of a defibrillator

Manual control mode

Discharge energy level

External electrodes:

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 300, 360 J

Time of the automatic category

60 seconds

Duration of charging is up to 360 J

Within 8 seconds with a rated voltage of a network/tension of a network of a direct current

Within 9 seconds with completely charged battery

* Data on charging duration in other cases see in the technical specification of a defibrillator

CHSS

Measuring range

From 0, 20 to 300 ud. / min.

Permission

1 ud. / min.

Accuracy

± 10% or ± 5 beats per minute that it is more

Average time of expectation

5 seconds (from 80 do120 ud. / min. )

9 seconds (from 80 to 40 ud. / min. )

Excessive deviation of the T - tooth

Amplitude of the T - tooth is no more than 1.8 mV

ECG (Elektrokardiograf)

Assignments

3 / 5 / 12 Assignment (Assignment of I, II, III, aVR, aVL, aVF, V, V1, V2,

V3, V4, V5, V6)

Utyuzhkovy electrode / electrode

Assignment shutdown detection

It is found and displayed

Detection of a pacemaker

Finds pacemaker impulses from ±2мВ to ±700мВ, lasting impulse from 0.1 to 2 ms and time of increase of 10% of duration no more than 100 ms

Input data

Impedance of an entrance electrode

5 Megohm or more

Dynamic range on an entrance

±5 mV alternating current, ±300 mV direct current

Range of tension

±0.5 mV ~ ±5 mV

Signal width

From 40 to 120 ms (from Q to S)

Output

Filter mode

От 0.5 до 21 Hz

От 0.05 до 40 Hz

От 1 до 21 Hz

ECG size

Car, 5.0, 10.0, 15.0, 20.0, 30.0 mm/mV

Display rate of display

25.0 mm / with

Tooth size

x0.5, x1, x1.5, x2, x3

Sensitivity of the display

10 mm/mV (x1)

Detection of impulses of cardiostimulation

It is included, switched off

Warning sign of a detachment of an electrode

Display and/or sound signal

Extinction coefficient of a cophased signal

90 dB or more

Category of a defibrillator

Recovery of operating state

Protection of a defibrillator

Protected

Breath of IM

Method

Impedance pneumography

Range

From 0,3 to 120 breaths/min.

Permission

1 breath/min.

Assignments

From software to LP

Basic impedance

От 500 до 2000 Ohm

Delta impedance

От 0.5 до 3 Ohm

Assignment shutdown conditions

It is revealed and displayed

Protection of a defibrillator

It is protected

Display rate of display

25 mm / with

Tooth size

x0.5, x1, x1.5, x2

Breath of AW

Method

Not dispersive infrared spectroscopy

Range

From 0 to 150 breaths/min.

Accuracy

±1 breath/min.

Pulse rate range

Adults/children

From 40 to 200 ud. / min.

Newborns

From 40 to 240 ud. / min.

Permission

5 ud. / min.

Accuracy of measurement of state of emergency

±2 ud. / min. Or ±2% , depending on what value is more

NIAD (Noninvasive arterial pressure)

Method

Ostsillometrichesky method of measurement

Mode of measurements

It is switched off, continuously, 1, 2.5, 3, 5, 10, 15, 30, 60, 90 minutes

Measuring range

Adults/children

Systolic

from 60 to 250 mm of mercury.

Average

from 45 to 235 mm of mercury.

Diastolic

from 40 to 200 mm of mercury.

Newborns

Systolic

from 40 to 120 mm of mercury.

Average

from 30 to 100 mm of mercury.

Diastolic

from 20 to 90 mm of mercury.

Accuracy of measurement of NIAD

Average error and standard deviation on ANSI/AAMI

SP10: 2002 + A1: 2003 + A2: 2006

Range of display of pressure

Adults/children

from 0 to 300 mm of mercury.

Newborns

from 0 to 150 mm of mercury.

Display of data on pressure (accuracy)

Within ±3 mm hg or 2%

Initial pressure of air in a cuff

 

Adults/children

120, 140, 160, 180, 200, 220, 240, 260, 280 mm of mercury.

(16.0, 18.7, 21.3, 24.0, 26.7, 29.3, 32.0, 34.7, 37.3 kPa)

Newborns

80, 90, 100, 110, 120, 130, 140 mm of mercury.

(10.7, 12.0, 13.3, 14.7, 16.0, 17.3, 18.7 kPa)

Automatic sduvaniye of a cuff

The measurement time exceeding 180 with at adults/children (90 with at newborns) or the maximum value of pressure exceeding 300 mm of mercury. at adults (150 mm of mercury. at newborns).

Protection against excessive pressure

Adults/children: 300 mm of mercury. Newborns: 150 mm of mercury.

Protection of a defibrillator

It is protected

Measurement speed

About 20 seconds

Under following conditions:

Adults

The size of a cuff is 12 cm

Systolic 120 mm of mercury.

Average of 90 mm of mercury.

Diastolic 80 mm hg / state of emergency 80 ud. / min.

Measurement in the manual mode (180 mm of mercury. )

 

IAD 

Pulse rate

Pulse rate range

From 20 to 250 ud. / min.

Accuracy

± 1% or ± 1 ud. / min.

Permission of pulse rate

1 ud. / min.

IAP (Invasive Arterial Pressure)

The displayed indicator

P1, ABP

P2, CVP, PAP, LAP

Measuring range

From - 50 mm of mercury. to 300 mm of mercury.

From 20 ud. / min. to 250 ud. / min.

Permission

1 mm of mercury.

Accuracy

± 3 mm of mercury.

Entrance sensitivity

5 mkv/v/mm рт. ст.

Volume shift of the sensor

0.1 mm3/100mm hg.

Range of calibration of zero

± 100 mm of mercury.

Frequency characteristic

Direct current - 10 Hz ± 1 Hz, - 3 dB

Tooth size

From 0 to 50, from 0 to 100, from 0 to 200, from 0 to 300, car size

Display rate of display

25.0 mm / with

Protection of a defibrillator

It is protected

SpO2 

Measuring ranges

Area of saturation SpO2

1% to 100%

Range of measurement of state of emergency

From 20 to 300 beats per minute (ud. / min. )

Contact the seller
Defibrillator – the D500 monitor
Defibrillator – the D500 monitor
Shipping method
Payment method
Compare0
ClearSelected items: 0