Currency KZT
I-160MI ionomer buy in Almaty
Buy I-160MI ionomer
I-160MI ionomer

I-160MI ionomer

In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Kazakhstan, Almaty
(View map)
+7(7 
Display phones
7
7 years on Allbiz
Quickly responds
Description

I-160MI ionomer


As well as the majority of similar ionomers, I-160 MI works in the dialogue mode and consists of several components: the converter (turns on the TDL-1000-06 thermal sensor, ES-10603/7 rn-electrode, an electrode of comparison ESR-10103), the power supply unit and a support. Gives the chance to take automeasurements, continuous measurements, and also measurements with the set duration.


The main advantages of the I-160 MI device are its compatibility with the majority domestic and import ion-selective and rn-electrodes, and also a possibility of the analysis and data processing on the personal computer. The ionomer carries out automatic processing of results of measurements and indication in all possible units.


- The ionomer allows to take measurements with the set duration; continuous measurements; and measurements with automatic detection of the termination (automeasurement).


 - I-160 MI is easy-to-work, works in the dialogue mode with use of hints to the operator. 


  - Expeditious self-diagnostics, control of parameters of electrode system, results and time of control is used.


 - The possibility of carrying out multipoint control is provided in an ionomer.


 - I-160 MI allows to make the preliminary choice of algorithm of operation of the device in the modes of control and measurement. In memory of the device techniques of the performed measurements, including methods of additives are put.


 - In memory of an ionomer adjusting constants of nine electrode systems remain.


 - The possibility of the analysis and data processing on the personal computer is provided. In memory it can be kept up to 100 results of measurements.


 - Use of interchangeable thermal sensors allows not to carry out control of an ionomer at their replacement.







































The measured size



Units of measure



Range of measurements



Discretization



Converter error



Device error



pX



-



- 20,000. 20,000 *



* 0,001



±0,014 (Ion±1), ±0,028 (Ion±2)



±0,05



pH



-



- 1,000. 14,000 *           



* 0,001



±0,014



±0,03



Eh (EMF)



mV



- 3000,0. 3000,0



0,1



±0,7



 



cX



g/l, g/kg, mol/l, mol/l ekv.



10-6. 100 *



automatically



monovalent ±2,5%


 bivalent ±5%



 



T



°C



- 20,0. 150,0 *



0,1



±0,5



±0,5


 


* Range of indications of the converter. Range of measurements depends on the applied electrode.


Control on one – five solutions


Exit: digital    C2 (RS-232C)


analog  2V; 100mV


Error of output voltage of ±0,25%


Display graphic ZhKI


Food of 220 V, with a frequency of 50-60 Hz


Weight is 1,5 kg


 Delivery set:


1) I-160 MI converter


2) TDL-1000-06 thermal sensor


3) ES-10603/7 rn-electrode


4) Electrode of comparison ESR-10103


5) Set of devices for carrying out measurements


6) ShU-05 support


7) Grid power supply unit


8) Form


9) Operation manual

Contact the seller
I-160MI ionomer
I-160MI ionomer
Shipping method
Payment method
Compare0
ClearSelected items: 0