The KMP Memphis AT mammography system is a modern, reliable mammography system, with a low exposure dose and high resolving power which provides the high-quality image of a mammary gland necessary for exact diagnostics.
Provides unsurpassed quality of the image and has lungs in management of function.
Advantages:
Operational panel:
The KMP Memphis AT operational panel is the most intellectual part of system. You can see all necessary values on the full-colored LCD monitor.
Automatic targeting:
KMP Memphis AT has system of automatic targeting which is specially developed for increase of convenience of control of the mammographer. Function of automatic targeting gives the chance to execute procedure from 4 different positions in the unique patented way.
Compression MICOM system:
KMP Memphis AT allows to carry out procedure with comfortable degree of a compression. When a certain level of pressure of KMP Memphis AT is necessary for the operator can pick up it (from 10 N to 300 N), also the controlled Soft-touch MICOM system for reduction of discomfort of the patient when carrying out procedure is built in it.
Automatic control system of exposure:
With this system becomes possible to create pictures with the necessary intensity for different methods of radiography
Access to increase in the image:
KMP Memphis AT has the built-in system of increase. It defines the best distance for obtaining high-quality images.
Features:
- Stable signal, secure
- high-frequency reformative
- system
- The generator which is built in the body
- System of automatic targeting
- SID for the quality image
- Convenient use of the LCD panel
- Automatic dumping of pressure after use
- Highly sensitive Fiber Grid Bucky device
- AEC mode
- 15-level monitoring system
- The convenient compression MICOM system with the sensor
Name | KMP Memphis AT mammography system |
X-ray generator | |
Type | High-frequency inverter of 5 kW |
Radio graphic data | Big focus of 20-35 kV (step to 1 kV) / 4-500 Mas; Small focus of 20-35 kV (step to 1 kV) / 4-160 Mas; |
Controller | |
Type | Microprocessor control Digital display |
Modes | Manual and microprocessor automatic control of exposure (AES) |
Installation of a voltage | 22-39 kV |
Detector | Diode |
X-ray tube | |
Rated voltage | 50 kV |
Target corner | Big 16 ° and small 10 °. |
Filtering of radiation | 0,63 mm of Be |
Nome-noye value of a focal point | 0,1/0,3 mm. |
Heat capacity of the anode | 300 kJ |
Heatdispersion of the anode | 60 kJ/min. |
Range of heat of current | Big focus 3.0 ~ 4.2 A; Small focus 3.0 ~ 3.8 A |
Range of heat of tension | Big focus 3.6 ~ 6.5 B; Small focus 2.8 ~ 5.8 B |
Filter | |
Types of filters | Molybdenic filter / Rhodic |
Inclusion method | Automatic inclusion at installation of a voltage |
Radio graphic stand | |
Vertical movement | 780 mm (550 ~ 1 330 mm) are made by the electric drive. |
Rotation | Rotation is made by the electric drive 180 ° 140 ° to the left to the right. |
Force compression | Manually 280 N; electric drive of 200 N |
Requirements to the power supply | |
Entrance tension | 220-240 V |
Power consumption | 4,2 kW 25A in 5 seconds of work |
Rubbed. moshch-st in a waiting mode | 0,8 kV nominally |
Operating mode | Full loading of 5 seconds, 120 seconds it is switched off |
- Stable capacity thanks to invertor system of the generator
- Microprocessor automatic control of exposure
- Automatic removal of a compression after exposure the organic signal provided with high-frequency reformative system
- The generator which is built in the body
- Optimum focal length of the quality image
- Convenient use of the LCD panel
- Automatic dumping of pressure after use