(View map)
- BrandЗавод электротехнического оборудования ЗАО "ЗЭТО""
- Country of manufactureRussia
- provide effective restriction of retension;
- are explosion - proof;
- vibroprochna and aseismic;
- possess high stability of characteristics;
- have small dimensions and weight;
- are reliable.
Appointment:
- for protection of isolation of electric equipment of substations and networks on classes of tension of 0,4 and 0,66 kV from switching and atmospheric retension;
- for protection of electric equipment of distributive networks of 3, 6, 10 kV of alternating current with the isolated or compensated neutral from storm retension;
- for protection of motive loading in networks of 3, 6, 10 kV from storm and switching retension;
- for protection of cable networks, motive and transformer loading in industrial networks of 3, 6, 10 kV from storm and switching retension;
- for protection of transformer loading and other electric equipment in air distributive networks of 3, 6, 10, 15, 20, 35 kV from storm and switching retension;
- for protection of electric equipment on classes of tension of 110, 150, 220, 330 and 500 kV working in a network with the grounded neutral, with effectively grounded neutral from grozovy and switching short circuits;
- limiters of retension of the OPNN - P series are intended for protection of a razzemlenny neutral of transformers and high - voltage devices on tension classes 110, 150 and 220 2 - 4 classes of capacity included in this neutral from storm and switching retension.
Service conditions:
- operation in the conditions of open air or in rooms;
- ambient temperature: - 60 - + 50 °C;
- installation height above sea level: to 1000 m;
- relative humidity of air at a temeratura of 25 °C: to 100% ;
- ice crust thickness: to 20 mm;
- wind speed without ice: no more than 40 m/s. ;
- wind speed at ice: no more than 15 m/s.
Nomenclature:
1. for protection of isolation of electric equipment of substations and networks with a glukhozazemlenny neutral from atmospheric and switching retension.
OPN - P - 0,38UHL1
OPN - P - 0,66UHL1
OPN - P - 0,38UHL1
OPN - P - 0,66UHL1
2. for protection of isolation of electric equipment against atmospheric and switching retension (transformers, the rotating machines, cables, arc furnaces) in networks with the isolated neutral.
OPN - P1 - 3/3,0/10/2UHL1(2)
OPN - P1 - 3/3,3/10/2UHL1(2)
OPN - P1 - 3/3,6/10/2UHL1(2)
OPN - P1 - 6/6,0/10/2UHL1(2)
OPN - P1 - 6/6,6/10/2UHL1(2)
OPN - P1 - 6/6,9/10/2UHL1(2)
OPN - P1 - 6/7,2/10/2UHL1(2)
OPN - P1 - 10/10,5/10/2UHL1(2)
OPN - P1 - 10/11,5/10/2UHL1(2)
OPN - P1 - 10/12,0/10/2UHL1(2)
OPN - P1 - 15/18,0/10/2UHL1
OPN - P1 - 15/18,0/10/3UHL1
OPN - P1 - 20/24,0/10/2UHL1
OPN - P1 - 20/24,0/10/3UHL1
OPN - P1 - 35/40,5/10/2UHL1
OPN - P1 - 35/40,5/10/3UHL1
OPN - P1 - 35/44/10/3UHL1
3. for protection of isolation of electric equipment of distributive networks with the isolated or compensated neutral from grozovy retension.
OPN - 1(2) - 3/3,8IIIUHL1
OPN - 1(2) - 6/7,2IIIUHL1
OPN - 1(2) - 6/7,6IIIUHL1
OPN - 1(2) - 10/12IIIUHL1
OPN - 1(2) - 10/12,7IIIUHL1
OPNF - 6/7,2UHL1
OPNF - 6/7,6UHL1
OPNF - 10/12UHL1
OPNF - 10/12,7UHL1
4. for protection of isolation of electric equipment of 110, 150 and 220 kV against a grozovykha of switching retension in networks with the grounded neutral.
OPN - P1(2) - 110/73/10/2III (IV) UHL1
OPN - P1(2) - 110/77/10/2III (IV) UHL1
OPN - P1(2) - 110/83/10/2III (IV) UHL1
OPN - P1(2) - 110/88/10/2III (IV) UHL1
OPN - P1(2) - 110/73/10/3III (IV) UHL1
OPN - P1(2) - 110/77/10/3III (IV) UHL1
OPN - P1(2) - 110/83/10/3III (IV) UHL1
OPN - P1(2) - 110/88/10/3III (IV) UHL1
OPN - P1 - 110/73/20/4II * (III) UHL1
OPN - P1 - 110/77/20/4II * (III) UHL1
OPN - P1 - 110/83/20/4II * (III) UHL1
OPN - P1 - 110/88/20/4II * (III) UHL1
OPN - P1 - 150/100/10/2III (IV) UHL1
OPN - P1 - 150/105/10/2III (IV) UHL1
OPN - P1 - 150/115/10/2III (IV) UHL1
OPN - P1 - 150/100/10/3III (IV) UHL1
OPN - P1 - 150/105/10/3III (IV) UHL1
OPN - P1 - 150/115/10/3III (IV) UHL1
OPN - P1 - 150/100/20/4II * (III) UHL1
OPN - P1 - 150/105/20/4II * (III) UHL1
OPN - P1 - 150/115/20/4II * (III) UHL1
OPN - P1 - 220/154/10/2III (IV) UHL1
OPN - P1 - 220/163/10/2III (IV) UHL1
OPN - P1 - 220/172/10/2III (IV) UHL1
OPN - P1 - 220/154/10/3III (IV) UHL1
OPN - P1 - 220/163/10/3III (IV) UHL1
OPN - P1 - 220/172/10/3III (IV) UHL1
OPN - P1 - 220/154/20/4II * (III) UHL1
OPN - P1 - 220/163/20/4II * (III) UHL1
OPN - P1 - 220/172/20/4II * (III) UHL1
OPN - P1 - 220/154/20/5II * (III) UHL1
OPN - P1 - 220/163/20/5II * (III) UHL1
OPN - P1 - 220/172/20/5II * (III) UHL1
OPN - P1(2) - 330/210/10/3II * (III) (IV) UHL1
OPN - P1(2) - 330/220/10/3II * (III) (IV) UHL1
OPN - P1(2) - 330/230/10/3II * (III) (IV) UHL1
OPN - P1(2) - 330/210/20/4II * (III) (IV) UHL1
OPN - P1(2) - 330/220/20/4II * (III) (IV) UHL1
OPN - P1(2) - 330/230/20/4II * (III) (IV) UHL1
OPN - P1(2) - 330/210/20/5II * (III) (IV) UHL1
OPN - P1(2) - 330/220/20/5II * (III) (IV) UHL1
OPN - P1(2) - 330/230/20/5II * (III) (IV) UHL1
OPN - P1(2) - 500/318/20/4III (IV) UHL1
OPN - P1(2) - 500/336/20/4III (IV) UHL1
OPN - P1(2) - 500/318/20/5III (IV) UHL1
OPN - P1(2) - 500/336/20/5III (IV) UHL1
5. for protection of a razzemlenny neutral of transformers and high - voltage devices.
OPNN - P1 - 110/60/10/2III (IV) UHL1
OPNN - P1 - 110/60/10/3III (IV) UHL1
OPNN - P1 - 150/77/10/2III (IV) UHL1
OPNN - P1 - 150/77/10/3III (IV) UHL1
OPNN - P1 - 220/120/10/2III (IV) UHL1
OPNN - P1 - 220/120/10/2III (IV) UHL1
6. for protection of electric equipment of traction substations, posts of sectioning and points of parallel connection.
OPN - 3,3O1
7. for protection of a contact network of a direct current on a class of voltage of 3,3 kV from atmospheric retension;
for protection of devices of the electrified railroads of alternating current with a rated voltage of 27,5 kV, including a contact network, from atmospheric and switching retension.
OPNK - P1 - 3,3UHL1
OPNK - P1 - 27,5UHL1