Multicomponent batchers of the XM 70 series
- Customer pickup,
- Courier
- In detail
- Application MethodPneumatic
MULTICOMPONENT BATCHERS OF THE XM 70 SERIES
- Intuitive clear elements of management
- Provides display of a ratio of components in real time for final adjustment of the grant.
- USB port for data transmission
- The mixing block
- Provides exact mixing and exact regulation of a ratio even at a high consumption of material
- The choice between a standard and portable arrangement is possible
- The gun - the XTR - 7 spray
- The system allows use of several guns sprays for increase in productivity
- The basic model includes the gun spray, a hose and the static mixer.
Sizes
Basic …………………………………………………… model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . (without bunkers) 99shkh178vkh97g cm
Range of a ratio of components in mix … …. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . from 1: 1 to 10: 1 (with a step 0,1)
Dosage accuracy … … … … … … … … … … … … … … … … … … … … … … … … … …. + / - 5%
Giving
At least … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … …. . . 0,95 l/min *
At most ………………………………………………………. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11,4 l/min *
* Real giving depends on type and viscosity of material
Entrance for ……………………………………………………………………… air. ¾ npt (female thread)
Entrances for liquid without material supply sets … … … … 1 - 1/4 npt (an external carving)
Maximum working pressure of the liquid mix ………………. … …. 434 bars
Air pressure range on an entrance ………………………………………. from 3,5 to 10,3 bars
The maximum established pump air pressure … … … …. . . 6,2 bars
The maximum pressure of liquid on a pump entrance … … … … … ….17 bars
The maximum consumption of air with a pressure of 7,0 bars … …. . . 0,56 m3/min.
Weight … … … … … … … … … … … … … … … … … … … … … … … … … … … … …. 526 kg
This model approved for use in explosive zones.