Currency KZT
Paper for an ECG of devices (developing "accordion") buy in Almaty
Buy Paper for an ECG of devices (developing "accordion")
Paper for an ECG of devices (developing "accordion")

Paper for an ECG of devices (developing "accordion")

In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Kazakhstan, Almaty
(View map)
+7(7 
Display phones
9
9 years on Allbiz
Quickly responds
Description

Paper for an ECG of devices developing "accordion".

Carrying out diagnostics of cardiovascular system requires not only the corresponding medical equipment - the electrocardiograph, but also qualitative note paper of cardiograms. This expendable material is steadily used already many decades for registration of indications of cordial activity of the patient. Paper for an ECG differs in the high density and convenience in use.

Different devices ECG use the following options of paper: rolled, developing ("accordion") and disk. The main characteristics of paper – its length, width and density (thickness). For example, the average thickness of disk paper – 300 mm, rolled – about 250 mm.

Depending on drawing a tag and availability of perforation emit paper: 

  • without drawing a chart grid;
  • with a tag from a grid or a thermosensitive layer;
  • with a tag from a reverse side of a grid or a thermosensitive layer;
  • with a tag from two parties;
  • with perforation;
  • with double perforation.

 The printers which are built in devices ECG can carry out the ink and thermal press. The last – record on a thermal paper – is used in the most modern models of cardiographs. The thermal paper consists of several layers, has high quality of the press and protection of the image. In thermal printers are not used blackened, cartridges, a source of color is paper. But it is important to remember that such paper by definition is influenced by differences of temperatures, and it is recommended to store it at the room temperature to 30 degrees. Besides, the thermal paper differs in higher cost in comparison with the analog intended for the ink press.

Correctly to choose paper for the electrocardiograph, it is necessary to study the registration certificate of the device and the characteristic of an expendable material specified by the producer on packaging.

Technical characteristics:

Size Description
50 x 100 x 300 (FQS 50-3-100) Nihon Kohden defibrillators
Cardiolife NK 201/C ECG, TEC 7100/7200/7721K
80 x 70 x 315 M (with a tag) plotn. 55 g/m2   Schiller Cardiovit AT-101
 
80 x 70 x 315 M (with a tag) plotn. 70 g/m2  
 
80 x 90 x 250 M (with a tag) plotn. 70 g/m2 Electrocardiographs of the 3rd kanaln.  MAC 400, MAC 600
80 x 90 x 280 M (with a tag) plotn. 70 g/m2   MAC electrocardiograph of the 400, 3 channel
 
90 x 90 x 200 M (with a tag) plotn. 70 g/m2 Bi-phase defibrillator of ZOLL firm
Models – M Series, E Series
 90 x 90 x 266 M   Schiller Cardiovit AT-104 PS, 3 channel ECG
90 x 90 x 400 M (with a tag) Schiller Cardiovit AT-1 (the 3rd channel)
110 x 100 x 200 M (with a tag)   Bioset 3600/3601/3700
 
110 x 140 x 142 Ch M (pure with a tag) (FQW 110-2-140) Nihon Kohden, Cardiofax GEM (6 channel)
ECG - 9010K, ECG - 9020K, ECG - 9022K, ECG-1250
110 x 140 x 142 M the OP222TE code (with a tag)   Fukuda Denshi CardioMax FX-7202
 
110 x 140 x 144 M (with a tag) Dixion ECG-1006
110 x 140 x 200 M (with a tag) plotn. 70 g/m2    The MAC 800, 6 electrocardiograph is channel
 
112 x 100 x 150 Fetalis KMP-FM-01, KMP-FM-02 monitor
112 x 120 x 250 (grid of blue color)   Fetalis BFM-800 monitor
BIONICS Co. LTD. (BIOSYS), Yu.Korey
 
120 x 120 x 250 (grid of blue color) Monitor of function of a fruit IFM-500 (BIOSYS), Yu.Korey
130 x 120 x 250   Fetalis prenatal embryonal monitor
"BT-300D", Bistos Co., Ltd – Yu. Korea 
 
143 x 150 x 300 Ch M (pure, two tags) Fetalis monitor "Sonicaid Team Duo"
150 x 100 x 150 M (with a tag)   Avalon FM 30 (Philips) – the fetalis monitor
Hewlett Packard  (Philips) M 1911, M 1351FM
 
152 x 90 x 150 code 4305 BAO.DAO Fetalis monitor
"COROMETRICS 170" ("KOROMETRIKS 170")
152 x 90 x 160 code of paper 4305 AAO   Fetalis monitors:
"COROMETRICS 170" ("KOROMETRIKS 170")
"Overtone 6200" ("Overton 6200")
 
 
210 x 140 x 156 M (with a tag) plotn. 70 g/m2 ECG of Schiller CardioLaptop AT-110, 12 channel
Schiller Cardiovit AT-10 plus, 12 channel
210 x 140 x 200 M (with a tag)   Fukuda Denshi FX 4010
 
210 x 140 x 250 M (with a tag) Schiller Cardiovit AT-10, 6 channel
210 x 140 x 200 Ch M (pure with a tag) (FQW 210-3-140 code)    Nihon Kohden Cardiofax Q ECG 9110K/9130K/9132K (12 channel)
 Cardiofax M ECG 1350 (12 channel)
 
 
210 x 150 x 200 M (with a tag) Cardiette ar 2100 view
210 x 150 x 200 WC (pure, with a tag)   Nihon Kohden ECG 1550Cardiofax V (12-15 kanaln.)
 
210 x 280 x 180 M (with a tag) plotn. 55 g/m2 Schiller Cardiovit AT-102 (6/12 channel)
210 x 280 x 180 M (with a tag) plotn. 70 g/m2
210 x 280 x 215 M (with a tag)   Schiller Cardiovit AT-2/AT-2plus, Cardiovit CS-200
 
210 x 280 x 250 M (with a tag) BTL-08 LT Plus ECG, BTL-08 LC Plus ECG
(12-kanaln.)
210 x 280 x 300 About (with an oval opening) density is 70 g/m2   MAS-5000, 12-15 channel ECG
 
 
210 x 295 x 250 WC (pure with a tag) (FQW 210-10-295)  Nihon Kohden, (12 canal)
 Cardiofax V ECG 9320K
210 x 300 x 150 M (with a tag) plotn. 70 g/m2   MAC 1200, 6/12 - channel
 
210 x 295 x 150 M (with a tag) plotn. 70 g/m2 MAC 1200 ST, 6/12 – channel
(Hellige Cardiosmart)
210 x 300 x 200 (two square openings), Italy    Siemens MEG Burdick E-350
 
210 x 300 x 200 (with ovaln. opening, 1/3 leaves pure), Italy HEWLETT PACKARD (PHILIPS)
M1709A, M1700, M1701A,
 M2481A, M2483A, M3708A
215 x 280 x 200 M (with a tag) plotn. 70 g/m2   YM812i Mediana ECG, 12 channel
 
Contact the seller
Paper for an ECG of devices (developing "accordion")
Paper for an ECG of devices (developing "accordion")
Shipping method
Payment method
Compare0
ClearSelected items: 0