Currency KZT
Roofing works (services) order in Kyzylorda
Order Roofing works (services)
Roofing works (services)

Roofing works (services)

Reconfirm the price with seller
Seller
Kazakhstan, Kyzylorda
(View map)
Description

Roofing works (services)

Name of works

Unit of measure Cost (contractual)
Installation of a smooth faltsevy roof on an unary fold sq.m
Installation of a smooth faltsevy roof on a double fold (manually) sq.m
Installation of a smooth faltsevy roof from rolled metal sq.m
Production and installation of stationary trenches (with filing to pictures on an unary fold) item m.
Production and installation of stationary trenches (with filing to pictures on a double fold) item m.
Production and installation of end at a bias more than 30% (with filing to pictures on an unary fold) item m.
Production and installation of end at a bias less than 30% (with filing to pictures on a double fold) item m.
Installation of rafter system sq.m
Antiseptirovany, antiperirovany wooden designs sq.m
The device of an obreshetka from a board sq.m
Waterproofing device sq.m
Laying of a heater (the general thickness is 20 cm) sq.m
Laying of a heater (the general thickness is 15 cm) sq.m
Vapor barrier device sq.m
Production and installation of aprons of an adjunction under an otter item m.
Production and installation of aprons of an adjunction with a shtrobirovaniye item m.
Dismantle of a protective protection item m.
Galvanization dismantle sq.m.
Dismantle of an obreshetka sq.m.
Small repair and covering of a protection primer item m.
Installation of a protective protection item m.
Installation of pro-spirits and flyugarok of subroofing ventilation piece.
Production and installation of a protective box of a pipe and vent. mines sq.m (zagot.)
Installation of umbrellas and caps on pipes (to 650х650) piece.
Installation of the ridge device for fastening of the safety equipment item m.
Assembly and dismantling of the stationary woods m2fas
Installation of a cap on a chimney pipe / vent. mine piece.
Insert vent. / sewer driving / antenna conclusion piece.
Installation of a cap on a column piece.
Installation of a dormer-window piece.
Name Measurement unit.
Insert of a dormer-window in a ready roof piece.
Installation of window eaves rm.
Filing of eaves sves rabbeted board rm.
Installation of garret ladders rm.
Repair of a simple roof with full replacement of the existing covering by a covering from sheet galvanized steel and partial (to 20%) replacement of an obreshetka sq.m.
Repair of a roof of average complexity with full replacement of the existing covering by a covering from sheet galvanized steel and partial (to 20%) replacement of an obreshetka sq.m.
Repair of a roof of average complexity with full replacement of the existing covering by a covering from rolled galvanized steel with fastening in a double fold and replacement of an obreshetka (to 20%) sq.m.
Laying of a metal tile, professional leaf, professional flooring sq.m
Euroslate laying sq.m
Installation of rafter system sq.m
Antiseptirovany, antiperirovany wooden designs sq.m
The device of a draft obreshetka from board/plywood sq.m
Installation of a kontrobreshetka sq.m
The device of a continuous obreshetka from whetstone (a step of 30 cm) sq.m
Waterproofing device sq.m
Laying of a heater (the general thickness is 20 cm) sq.m
Laying of a heater (the general thickness is 15 cm) sq.m
Vapor barrier device sq.m
Laying of the fad with a sealant rm.
Endova device rm.
The endova device with a slip rm.
Installation of an eaves level rm.
Installation of a pediment level (vetrovik) rm.
Device of adjunctions to walls rm.
Installation of a cap on a chimney pipe / vent. mine piece.
Insert vent. / sewer driving / antenna conclusion piece.
Installation of a cap on a column piece.
Installation of a weather vane piece.
Installation of a dormer-window piece.
Insert of a dormer-window in a ready roof piece.
Name Measurement unit.
Filing of pediment carrying out by a spotlights or siding rm.
Installation of window eaves rm.
Filing of eaves sves rabbeted board rm.
Installation of garret ladders rm.
Opening of air and water bubbles, removal of moisture, drying of the opened places sq.m.
Repair of a roof in 1 layer, including partial opening of an old roofing carpet (to 20%) sq.m.
Repair of a roof in 2 layers, including partial opening of an old roofing carpet (to 20%) sq.m.
Repair of a roof in 2 layers, including full removal of an old roofing carpet and repair of a coupler by places (to 20%) sq.m.
Roof paving in 2 layers on the ready basis sq.m.
Roof paving in 2 layers with production of not reinforced cement and sand coupler 50 mm thick sq.m.
The roof device in 2 layers with production of the reinforced cement and sand coupler 50 mm thick, warming of minplity PPZh-200 150 mm thick and 2-layer vapor barrier sq.m.
Roof paving in 2 layers with production of the reinforced cement and sand coupler 50 mm thick, warming of minplity PPZh-200 150 mm thick, 2-layer vapor barrier, the razuklonka device from expanded clay with an average thickness of 100 mm sq.m.
Full dismantling of the existing roof (a waterproofing covering, a coupler, a heater) with garbage removal sq.m.
The device of a two-layer roofing carpet the built-up rolled material on a vertical surface sq.m
The thermal insulation device from plates 150 mm thick sq.m
Device of a cement and sand coupler up to 50 mm thick sq.m
The device of the reinforced cement and sand coupler up to 50 mm thick sq.m
Ogruntovka of the basis primer sq.m
The razuklonka device from expanded clay with an average thickness of 100 mm sq.m
The device of vapor barrier of the built-up single-layer sq.m
Vapor barrier device dry sq.m
Installation of water waste funnels piece
Installation of aerators roofing, deflectors piece
Parapet up to 500 mm wide paving galvanized steel m
The apron device from galvanized steel on adjunctions of a roofing carpet to vertical surfaces m
Laying of a flexible tile (Katepal, Tegola, etc.) sq.m
Laying of a natural tile sq.m
Installation of a copper tile sq.m
Installation of rafter system sq.m
Antiseptirovany, antiperirovany wooden designs sq.m
Name Measurement unit.
The device of an obreshetka from board/plywood sq.m
Installation of a kontrobreshetka sq.m
The device of a continuous obreshetka from whetstone (a step of 30 cm) sq.m
Waterproofing device sq.m
Laying of a heater (the general thickness is 20 cm) sq.m
Laying of a heater (the general thickness is 15 cm) sq.m
Vapor barrier device sq.m
Laying of the fad rm.
Endova device rm.
Installation of an eaves level rm.
Installation of a pediment level (vetrovik) rm.
Device of adjunctions to walls (pipes) rm.
Device of an additional waterproofing sq.m
Device of the ridge aerator piece.
Device of the wall aerator piece.
Installation of the aerator piece.
Installation of a snegozaderzhatel rm.
Installation of water waste aprons rm.
Installation of a gutter rm.
Installation of drainpipes rm.
Device of the built-in gutter rm.
Installation of a dormer-window piece.
Insert of a dormer-window in a ready roof with a basalt covering piece.
Insert of a dormer-window in a ready roof with a copper covering piece.
Installation of a cap on a chimney pipe / an air shaft piece.
Installation of a cap on a tower piece.
Installation of an aeration cap on a tower piece.
Installation of a weather vane piece.
Installation of window eaves rm.
Filing of eaves sves rabbeted board rm.
Name Measurement unit.
Installation of garret ladders rm.
Roof waterproofing a membrane Krovlelol And in 1 layer sq.m
The vapor barrier device - 1 layer of isolayer sq.m
The thermal insulation device from plates of Penopleks of P-35 100 mm thick sq.m
The thermal insulation device from expanded clay thickness on average 150 mm sq.m
Laying of a road grid sq.m
The device of the leveling coupler 40 mm thick sq.m
Laying of geotextiles of TERAM density is 90 g/m2 sq.m
Laying of geotextiles of TERAM density is 90 g/m2 sq.m
Device of a protective coupler 30 mm thick sq.m
The device of monolithic can the plate reinforced by 2 grids of 4 VRI-100/100 10 cm thick sq.m
Filling dry cement and sand mix - 40 mm sq.m
Laying of paving slabs gray sq.m
Contact the seller
Roofing works (services)
Roofing works (services)
Compare0