The X - ray fluorescent spectrometer of modification of "SRV - 1V" is intended for express high - quality and quantitative determination of the content (mass fractions) of chemical elements in strong, liquid and powdery objects of a natural and artificial origin.

The X - ray fluorescent spectrometer of the SRV - 1V model represents the functionally complete measuring and accumulative complex placed in the all - metal case and is intended for work in stationary laboratory conditions.

Main analytical and technical characteristics of a spectrometer of modification of "SRV - 1V"

Range of the analyzed elements
with an atmospheric pressure:
in vacuum:
from Si to U
from Mg to U
Intervals of the determined contents
elements without preliminary
concoction:
n×10 - 4 — 100%
Range of the analyzed power
range:
1 — 36 kev
Analysis method: X - ray fluorescent power dispersive
Power permission of semiconductor
the detector on the line 5,9 kev
(depending on detector type):
150 — 180 ev
X - ray optical scheme of measurement: two - axial and / or three - axial (on Barcla)
The mass of the analyzed hinge plate (depending on
analytical task):
5 — 50 g
Time of the quantitative analysis of the 1st test: 1 — 15 min.
Own instrument error: no more than 1%
Types of the possible analyzed samples: liquid, firm, powders, filters, films
Power of a x - ray tube: 1 — 50 W
Cooling of a x - ray tube: air or water
Radiation safety: it is exempted from a regulation on a radiation factor
The number of at the same time loaded tests: 12
Measurement conditions: in vacuum or with an atmospheric pressure
Tension of a power line with zero
wire with a tolerance
from nominal rate:
220±10 V
Power consumption: no more than 300 W
Overall dimensions: no more 610×500×370 mm
Mass of a spectrometer: no more than 35 kg

Complete set of a spectrometer of the SRV - 1V model:

— main module of a spectrometer;

— the personal computer with the LCD monitor;

— laser printer;

— uninterruptible power supply unit and stabilizer of mains voltage;

— software set;

— accessories and accessories to preparation of radiators;

— package of technical documentation;

— copies of the certificate on a spectrometer as a gage;

— the approved checking technique;

— act of primary radiation inspection.