Currency KZT
The narcotic device Acoma the FO-20 S model with the respiratory ARF-900 (II) E block buy in Ust-Kamenogorsk
Buy The narcotic device Acoma the FO-20 S model with the respiratory ARF-900 (II) E block
The narcotic device Acoma the FO-20 S model with the respiratory ARF-900 (II) E block

The narcotic device Acoma the FO-20 S model with the respiratory ARF-900 (II) E block

In stock
Reconfirm the price with seller
Payment:
  • Cash,
  • Invoice payment,
  • Visa/Mastercard,
  • Cash on delivery,
  • MoneyGram,
  • Western Union,
  • Credit card
  • In detail
Shipping:
  • Customer pickup,
  • Courier,
  • Transport company
  • In detail
Seller
Kazakhstan, Ust-Kamenogorsk
(View map)
+7(7 
Display phones

Company rating

92% of positive reviews from 13
12
12 years on Allbiz
Technical characteristics
  • Country of manufactureJapan
Description

The device for anesthesia is intended for carrying out the general anesthesia during surgeries at the wide contingent of patients: both at adults, and at children.

It is applied in stationary medical and treatment - and - prophylactic institutions.

The narcotic and respiratory device FO - 20S with a possibility of use as the independent device IVL (with the respiratory ARF - 900 (II) E block.

Technical characteristics:

• The fan of lungs with electronic control of volume of the given air, the built - in function of memory for previously set parameters, such as functions of the assistant / dispatcher; • Ventilation method: Volume task, temporary recurrence;

• Ventilation modes: Controller, assistant/controller;

• Circulation volume: 200 ~ 900 ml;

• Respiration rate: 5 - 40 times/min. ;

• Minute volume: 1 - 20 l. / min. (at I/E the relation: 1: 2);

• I/E relation: 1: 0.5 ~ 1: 5;

• Norm of a flow: 5 - 65 l. / mines;

• Sensitivity of the trigger: - 1 cm of H2O;

• Protective valve: 20 ~ 60 cm of H2O (variable step);

• Concentration of oxygen: 21 ~ 100% ;

• Humidifier of Heating type 80VA;

• Circulation pressure measuring instrument: - 10 ~ 70 cm of H2O;

• Alarm alarm system: Low pressure of a breath, wrong installation, malfunction of power supply, malfunction of the processor;

• Pause of a sound alarm signal: 2 min. (only for an alarm signal with a low pressure of a breath).