Appointment
Explosion-proof lamps for luminescent induction lamps like QL, and also gas-discharge lamps are intended for the general lighting of fields, sea platforms, docks and plants in which emergence of explosive gases or dust is possible.
Features
- Application of a luminescent induction lamp like QL allows to cut down energy consumption and expenses on service. Service life of a lamp reaches 80 000 hours.
- Universal fastening on a bracket allows to install the lamp practically on any surface and at any angle.
- The extra-strong plafond with high transparency bears blow of 4 J at a temperature of -40 °C and allows hit of a cold stream of water on the working lamp without loss of strength characteristics.
- Corrosion-resistant materials with a special covering provide long service life.
- Possibility of a complete set of the lamp dome-shaped reflector.
- Two dimensions of the case depending on the power of the used lamps.
Light sources
- luminescent induction lamp like QL (LYuM.IND.)
- mercury lamp of a high pressure like DRL (RT.L.)
- sodium lamp of a high pressure like DNAT (NAT.L.)
- metalhalogen lamp like DRI (GAL.L.)
- LED lamp (SD.L.)
Case dimension | Luminescent induction lamp like QL LYuM.IND. | Mercury lamp of a high pressure of RT.L. | Sodium lamp of a high pressure of NAT.L. | Metalhalogen lamp of GAL.L. | LED matrix | Boss's type |
VELAN22-85 | 55, 85 W | 80, 125 W | 70, 100 W | 70, 100 W | 10, 15 W | E27 |
- | 250 W | 150, 250 W | 250 W | - | E40 | |
VELAN22-165 | 135, 165 W | 400 W | 400 W | 400 W | - | E40 |
Advantage of use of luminescent induction lamps like QL in comparison with other light sources
Type | Gas-discharge lamp like DRI, 250 W | Luminescent induction lamp like QL, 85 W |
Time of the first ignition of a lamp | 120s | 0.5s |
Time of repeated ignition of a lamp | 250s | 0.5s |
Power factor | 0,92 | 0,99 |
Frequency at which the lamp works | 50 Of Hz | 2.61mgts |
Illumination | 570 lx | 600 lx |
Existence of stroboscopic effect | Yes | No |
Color index, CRI | 60 | 80 |
Technical characteristics
Explosion protection marking: |
2ExdeIICT4 for lamps with power up to 300 W 2ExdeIICT3 for lamps with power over 300 W |
Pylevlagozashchita level: | IP65 |
Supply voltage: | 220B, 50 Hz |
Diameter of the brought cable: | The 10-14th |
Section of the connected veins: | 3kh (1-2,5mm ²) |
Power factor: - for QL lamps - for gas-discharge lamps at application kompensat |
cos φ ≥ 0,99 cos φ ≥ 0,92 |
Class of protection against defeat by electric current in accordance with GOST 12.2.007.0 | I |
Operation temperature: - for QL lamps - for gas-discharge lamps and LED matrixes |
from -40 °C to +50 °C from -60 °C to +50 °C |
Design
- The lamp consists of the aluminum case with a powder covering.
- Protective glass – heat-resistant, extra-strong, with high light-transmitting ability, fastens in an aluminum ring and is twisted in the lamp. The protective lattice is in addition applied to protection of glass.
- In the case the cartridge and terminal clips for power connection are established.
- Leading of a cable is carried out through an opening in a box of introduction office
- The universal system of fastening on a bracket which allows to install the lamp on a ceiling, on a wall, including at an angle, and also at top of columns is provided in the lamp. The possibility of transit laying of a cable is provided in the lamp.
- In and outside of the lamp grounding bolts are established.
Completeness of delivery
By default the lamp is completed with zapglushka with M25x1,5 carving.
Are in addition ordered:
Cable inputs:
- VK-H-VEL1BM-M25kh1,5-Ekhe for an armor cable;
- VK-H-VEL3-M25kh1,5-Ekhe for not an armor cable;
- VK-H-VEL1BMT-M25kh1,5-Ekhe-M25kh1,5 for an armor cable in a pipe or for accession
this cable in a metalsleeve by means of the MMRN-20 coupling;
- VK-H-VEL3T-M25kh1,5-Exd-M25kh1,5 for not an armor cable in a pipe or for accession
this cable in a metalsleeve by means of the MMRN-20 coupling.
At the order of the lamp it is necessary to consider that in the case of the lamp it is cut
M25x1,5 carving.
Structure of a symbol
VELAN22 – X2 X1 – X3 – X4 – X5
VELAN22 – the lamp explosion-proof for luminescent induction lamps like QL
X1 – type of the applied lamp
LYuM.IND. - luminescent induction lamp
NAT.L. – a sodium lamp of a high pressure like DNAT
RT.L. – a mercury lamp of a high pressure like DRL
GAL.L. – a metalhalogen lamp like DRI
SD.L. – LED lamp
X2 – the power of the lamp (W) used in the lamp
X3 – fastening type: With – on a bracket. T1-on a pipe.
X4 – a reflector:
TO - dome-shaped
UO-angular reflector
In the absence of a reflector, the index is not specified.
X5 – a type of a climatic modification and category of placement in accordance with GOST 15150:
U1 – for luminescent induction lamps like QL
UHL1 – for gas-discharge lamps
TU 3461-013-00213569-2009
Example of record of designation of the lamp with a luminescent induction lamp like QL with a power of 85 W, a climatic modification and category of placement U1:
"VELAN22-LYuM.IND.85-S-U1 lamp"