Wires and cords lighting PVSNG-LS
- Customer pickup,
- Courier
- In detail
- BrandКараганда Систем
- Country of manufactureKazakhstan
The wire is flexible, with copper veins, with isolation and a cover from polyvinylchloride plastic compound of the lowered fire danger.
Wires, are intended for connection of electrical machines and devices of household and similar application to an electric network by a rated alternating voltage to 380-660B and with a nominal frequency of 50 Hz., and also devices in conditions where requirements to the increased fire safety are applied.
- Climatic modification of wires of UHL and T, category of placement 4 in accordance with GOST 15150-69
- Execution cords At are intended for operation at ambient temperature: from -40 °do +40 °C
- Cords of other executions: from -25 °do +40 °C
- The maximum temperature of a conducting vein at operation: +70 °C
- Cords after endurance in water at a temperature (20±5) °C during 1 h have to pass test an alternating voltage of 2000 V of the frequency of 50 Hz within 15 min.
- Wires do not extend burning at single laying
Number and nominal section of veins, mm2 |
Nominal thickness, mm |
Outer diameter of a wire, mm |
the electric resistance of isolation at T=700C counted for 1 km of length, megohm, not less |
Settlement weight is 1 km, kg |
||
isolation |
covers |
Min. |
"Max. |
|||
2 x 0,75 |
0,6 |
0,8 |
5,7 |
7,2 |
0,011 |
74,6 |
3 x 0,75 |
0,6 |
0,8 |
6,0 |
7,6 |
0,011 |
92,3 |
4 x 0,75 |
0,6 |
0,8 |
6,6 |
8,3 |
0,011 |
115,0 |
5 x 0,75 |
0,6 |
0,9 |
7,4 |
9,3 |
0,011 |
147,0 |
2 x 1 |
0,6 |
0,8 |
5,9 |
7,5 |
0,010 |
85,1 |
3 x 1 |
0,6 |
0,8 |
6,3 |
8,0 |
0,010 |
106,0 |
4 x 1 |
0,6 |
0,9 |
7,1 |
9,0 |
0,010 |
137,0 |
5 x 1 |
0,6 |
0,9 |
7,8 |
9,8 |
0,010 |
169,0 |
7 x 1 |
0,6 |
1,0 |
9,3 |
12,0 |
0,010 |
199,0 |
2 x 1,5 |
0,7 |
0,8 |
6,8 |
8,6 |
0,010 |
115,0 |
3 x 1,5 |
0,7 |
0,9 |
7,4 |
9,4 |
0,010 |
149,0 |
4 x 1,5 |
0,7 |
1,0 |
8,4 |
10,5 |
0,010 |
191,0 |
5 x 1,5 |
0,7 |
1,1 |
9,3 |
11,6 |
0,010 |
243,0 |
7 x 1,5 |
0,7 |
1,2 |
11,0 |
14,0 |
0,010 |
282,0 |
2 x 2,5 |
0,8 |
1,0 |
8,4 |
10,6 |
0,0095 |
174,0 |
3 x 2,5 |
0,8 |
1,1 |
9,2 |
11,4 |
0,0095 |
225,0 |
4 x 2,5 |
0,8 |
1,1 |
10,1 |
12,5 |
0,0095 |
282,0 |
5 x 2,5 |
0,8 |
1,2 |
11,2 |
13,9 |
0,0095 |
356,0 |
7 x 2,5 |
0,8 |
1,2 |
13,0 |
17,0 |
0,009 |
425,0 |
2 x 4 |
0,8 |
1,1 |
9,7 |
12,1 |
0,0078 |
239,0 |
3 x 4 |
0,8 |
1,2 |
10,5 |
13,1 |
0,0078 |
311,0 |
4 x 4 |
0,8 |
1,2 |
11,5 |
14,3 |
0,0078 |
392,0 |
5 x 4 |
0,8 |
1,4 |
13,0 |
16,1 |
0,0078 |
506,0 |
The wire is flexible, with copper veins, with isolation and a cover from polyvinylchloride plastic compound of the lowered fire danger.
1.tokoprovodyashchiye veins correspond to a class 5 in accordance with GOST 22483-77
2. Isolation – from polyvinylchloride plastic compound of the lowered fire danger.
3. Digital marking is applied on the isolated veins of wires with number of veins 7
4. The isolated veins are twisted. The isolated veins of five-vein wires of the PVSNG-LS brand are twisted in the core around a plait extruded of polyvinylchloride plastic compound of the lowered fire danger.
5. A cover – from polyvinylchloride plastic compound of the lowered fire danger.