Wires and cords lighting ShVP, ShVPn
- Customer pickup,
- Courier
- In detail
- BrandКараганда Систем
- Country of manufactureKazakhstan
Cord with parallel copper veins with PVC isolation, the increased flexibility. ShVPn – the same, not intended for reinforcing by non-demountable fittings.
Cords of the ShVP brand are intended for connection of the radio-electronic equipment, household illuminants, electric devices of a microclimate, electromechanical household appliances, electric fans and other similar devices on tension to 380 V for systems 380/380 B if the cord often is exposed to easy mechanical deformations.
- Climatic modification in accordance with GOST 15150:
At – categories of placement 1, 2, 3
T – categories of placement 4
UHL – categories of placement 4
- Execution cords At are intended for operation at ambient temperature
from-40 to +40 °C
cords of other executions from-25 to +40 °C
- The maximum temperature of a conducting vein at operation: +70 °C
- Cords after endurance in water at a temperature (20±5) °C during 1 h have to pass test an alternating voltage of 2000 V of the frequency of 50 Hz within 15 min.
- Cords do not extend burning at single laying
- Rated current loads are specified in the Appendix
- The resource of cords expressed in resistance to sign-variable deformations of a bend with a rated voltage makes: not less than 30000 (60000) cycles (movements)
- The nominal stretching force and diameter of rollers corresponds specified in the Appendix.
- The established trouble-free operating time has to be not less than 3000 h
- Construction length of cords is not less than 50 m
- A warranty period of operation 2 years from the date of commissioning
- Service life of cords not less than 6 years
Number and nominal section of veins, mm2 |
Nominal thickness of isolation, mm |
The external sizes for cords of the ShVPn brand, mm |
The external sizes for cords of the ShVP brand, mm |
Settlement weight is 1 km of cords, kg |
||
isolation |
Min. |
Max. |
Min. |
Max. |
||
2 x 0,50 |
0,8 |
2,4x4,9 |
3,0x5,9 |
2,5x5,0 |
2.8x5,6 |
21,0 |
2 x 0,75 |
0,8 |
2,6x5,2 |
3,1x6,3 |
2,7x5,4 |
3,0x6,0 |
27,1 |
Cord with parallel copper veins with PVC isolation, the increased flexibility. ShVPn – the same, not intended for reinforcing by non-demountable fittings.
1. A conducting vein – copper or copper tinned (at the customer's request, at the order add the letter "l" to brand), a round form, multiwire a class 6 in accordance with GOST 22483.
2. Isolation – from plastic compound PVC, is imposed on in parallel the veins laid in one plane, with division between veins. Isolation thickness between veins not less than 1.6 mm. Colors of isolation of cords are specified in the appendix.