The X-ray apparatus of mobile "KMP Mobile X-Ray" with accessories — still more conforms to requirements of urgent delivery of health care, allowing to observe X-ray diagnostic testings in extremely short time. The mobile X-ray apparatus of "KMP Mobile X-Ray" can quickly be delivered to the place of research and freely be established in the most difficult conditions, for example, in narrow passes between beds. High quality of roentgenograms and simplicity in management are key characteristics of this reliable system.
The support of the device is ideally balanced. In combination with bolsherazmerny wheels, it allows to transport the device without essential efforts. The compact design characteristic of all model range of ward devices provides the good overview, reduces probability of arrival by an obstacle and increases safety of operation of system.
Big back wheels provide a possibility of transfer of the center of gravity of the device by means of easy pressing with a leg on a pedal. This reception allows the operator to raise without effort front wheels and to overcome small steps and thresholds, and also to drive freely in an elevator cabin.
The device is characterized by high maneuverability, it can be developed by 180 degrees on the small patch. High quality rentgnogramm, received by means of the ward device is provided thanks to the generator with the high-frequency inverter 60 kHz. Power of the generator is rather big for receiving informative pictures on a film or CR cartridges. At a X-ray analysis the operator can choose any of 72 programs of automatic equipment for bodies. Functionality of the device can be expanded by inclusion of such options as automatic control of exposure, a X-ray protective screen, the printer of parameters of exposure and the IK-remote control.
Features:
- High maneuverability
- Ergonomic design
- Simplicity in operation
- Compact design
- Intuitive management of movement
- Means of increase of safety
- Minimization of expenses of time for each research
- Extensive coverage zone
- Promotion of a sleeve
- Turn of the collimator
- Programming on bodies
- The central switch of locks for blocking and an unblocking of movements of a support of a tube
- Unlimited choice of focal length
- Precision positioning in the medlennogoperemeshcheniye mode.
- High quality of radiographic images
- High-frequency invertor power supply
- Decrease in beam loading
- High power of the generator
- New model of a X-ray tube with two focuses
Technical characteristics
- Smooth and quiet movement
- The technology of control of power allows to move the device easily and quietly.
- Compact design
- Excellent visibility allows to move freely even in the conditions of limited space.
- Easy installation
- The system can quickly and freely change situation with the help of the Inch movement button for movement of a X-ray tube on the main space and rotary columns.
- Standard of anatomic programs
- Anatomic programs are installed as the standard that will allow to set X-ray analysis parameters easily.
- Wireless systems
- The built-in accumulator provides x-ray images without turning on of the device.
- Condition of the indicator
- The status of the indicator burns or blinks in the mode of rentgensky radiation or at disturbances of work of system. It allows to control a condition of system visually.
- FPD updating (only 32 kW)
Technical characteristic of the main unit: | |
Maximum tension of a tube: | 32 kW are 133 kV; 12,5 kW are 125 kV |
Maximum current of a pipe: | 32 kW – 400 ma; 12,5 kW – 160 ma |
Maximum power: | 32 kW are 32 kV (20 ms); 12,5 kW – 12,5kv (0,1 c) |
Rated power: | 32 kW are 16 kV; 12,5 kW are 12,5 kV |
Power supply: | 32 kW are from 40 to 133 kV at increase in 1 kV 12,5 kW – ot40 to 125 kV at increase in 1 kV |
Setup Mas | 6.3, 7.1, 8.0, 9.0, 10, 11, 12,14,16, 18, 20, 22, 25, 28, 32, 36, 40, 45, 50, 56, 63, 71, 80, 90, 100, 110, 125, 140, 160, 180, 200, 220, 250, 280, 320 Mas |
Maximum mas for each kV | 32 kW |
For a case the general of a X-ray analysis: | |
Big focus |
40 to 90 kV: 320 Mas |
Small focus | 40 to 90 kV: 320 mas 91 to 100 kV: 280 mas 101 to 110 kV: 250 mas 111 to 120 kV: 220 mas 121 to 133 kV: 200 mas |
Long-term images | |
Big focus | 40 to 65 kV: 320 mas 66 to 80 kV: 280 Mas 81 to 85 kV: 250 Mas 86 to 100 kV: 220 Mas 101 to 105 kV: 200 Mas 106 to 125 kV: 180 Mas 126 to 133 kV: 140 Mas |
Small focus | 40 to 65 kV: 320 Mas 66 to 80 kV: 280 Mas 81 to 85 kV: 220 Mas 101 to 105 kV: 180 Mas 126 to 133 kV: 140 Mas |
Minimum exposition time | 32 kV: 1,0 m/s; 12,5 kV: 3,2m/sec. |
Anatomic programs | 32 kV: the general 72; 12,5 kV: the general 72 |